Mircom TX3 Series Guida Utente Pagina 22

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 61
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 21
22 (61) TX3-CX Card Access System Installation and Operation Manual Version 2.2
LT-980 Copyright 2015
Configurable Features
an access card with lock/unlock privileges, if swiped twice in succession,
toggles between lock and unlock mode
a schedule associated with the lock/unlock mode - when the associated
schedule is active, it changes to unlock mode and when the schedule is
inactive, it changes back to lock mode
Whenever the mode is changed from lock to unlock or from unlock to lock, the
beeper on the reader associated with this access point sends a distinct beep
indicating the mode is changed.
2.3.2 High security
The high security mode grants access to cards with the high security privilege.
This mode is changed as follows.
if the access point is configured as high security then it is in high security
mode by default unless changed by the PC or card with high security
privilege
if an access card with high security privilege is swiped four times in
succession, the mode toggles between high security on to high security off
the configurator software can change the mode from high security on to
high security off or from high security off to high security on
an event correlated with a response to turn on or off the high security mode
The high security mode locks all doors in the unlocked mode.
Whenever the high security mode changes, the beeper on the reader associated
with this access point sends a distinct beep.
2.3.3 PC decision required
During this mode the decision to grant access is transferred to an attendant. Using
the PC the attendant grants or denies access. Only valid cards assigned with the
PC decision requirement are able to make this type of access request.
2.3.4 Facility code mode
Access cards consist of two codes; facility code and card code. The facility code
mode is designed for new installations where access cards are not programmed
into the database. When the facility code mode is enabled, cards with same
facility code are granted access.
The facility code can be set to any number. If a number is not chosen, it will
automatically default to “0” as a placeholder.
In this mode, the door is unlocked for the same period of time that as that of the
standard door unlock timer. This mode is configured for each access point.